CMG-3ESPCD Digital Broadband Seismometer Command line interface
component letter (N) and a tap number (1). Unlike most FORTH commands,
the stream-id parameter goes after the command.
6.7.10 STATUS-ONLY
Syntax: STATUS-ONLY
Instructs the digitiser to transmit only status streams (text streams, normally
with stream IDs ending in 00.)
6.7.11 S/S
Syntax: rate S/S
Instructs the digitiser to transmit only streams with sample rates equal to
rate. If rate is zero, only status streams are transmitted. Note that this
command should not be confused with the SAMPLES/SEC command.
6.7.12 ALL-TIMES
Syntax: ALL-TIMES
Clears any time selection in force, allowing you to download all data held by
the digitiser. This command does not alter which streams are to be
transmitted; you should specify streams or use the ALL-DATA command in
addition to this one.
6.7.13 FROM-TIME
Syntax: yyyy mm dd hh mm FROM-TIME
Instructs the digitiser to transmit only data more recent than yyyymm-dd
hh:mm, where
yyyy is a four-digit year (1989 – 2069);
mm is the month number (1 – 12);
dd is the day of the month (1 – 31);
hh is the hour of the day (0 – 23); and
mm is the minute of the hour (0 – 59).
6.7.14 TO-TIME
Syntax: yyyy mm dd hh mm TO-TIME
Instructs the digitiser to transmit only data more recent than yyyymm-dd
hh:mm, where yyyy, mm, dd, hh and mm have the same meanings as in
FROM-TIME, above.
MAN-C3E-0002 74 Issue B - November 2013