CMG-3ESPCD Digital Broadband Seismometer Appendix A - Connector pin-outs
8.4 AUXILIARY port (optional)
This is a standard 19-pin “mil-spec” plug,
conforming to MIL-DTL-26482 (formerly
MIL-C-26482). A typical part-number is
02E-14-19P although the initial “02E” varies with
manufacturer.
Suitable mating connectors have part-numbers
like ***-14-19S and are available from Amphenol,
ITT Cannon and other manufacturers.
Pin Function Pin Function
A not connected L Signal ground
B not connected M not connected
C not connected N Digital ground
D not connected P User channel 1
E not connected R User channel 2
F not connected S User channel 3
G not connected T User channel 4
H not connected U User channel 5
J Auxiliary / calibration channel + V User channel 6
K Auxiliary / calibration channel -
Wiring details for the compatible socket,
***-14-19S, as seen from the cable end (i.e.
when assembling).
MAN-C3E-0002 94 Issue B - November 2013